Tel:
China Biomass Steam Boiler manufacturer
Henan Yuji Boiler Vessel Manufacturing Co., Ltd.

Adhering to Honesty and Foundry Quality

Home ProductsGas Fired Steam Generator

Safety Protection Steam Powered Electric Generator Wide Application

Safety Protection Steam Powered Electric Generator Wide Application

    • Safety Protection Steam Powered Electric Generator Wide Application
    • Safety Protection Steam Powered Electric Generator Wide Application
  • Safety Protection Steam Powered Electric Generator Wide Application

    Product Details:

    Place of Origin: China (Mainland)
    Brand Name: Yuji
    Certification: ISO CE
    Model Number: Gas&Oil Fired Steam Generator

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: Negotiable
    Packaging Details: wood packet
    Delivery Time: 15 days
    Supply Ability: 5 sets per month
    Contact Now
    Detailed Product Description
    Product Name: LSS Series LSS0.15 Stainless Steel Energy Saving Gas Fired Steam Generator Working Pressure: 0.4/0.7MPa
    Application: 151/171℃ Material: Industrial Production, School, Restaurant, Hospital, Sauna
    Output: Steam Usage: Industrial, School, Laundry, Restaurant, Hospital
    Type: Natural Circulation Warranty: 2 Years
    High Light:

    gas powered steam generator

    ,

    natural gas steam generator

    Product Discription

    LSS oil and gas fired vertical steam generator

     

    The vertical gas vapour generator for LSS fuel has a vertical tubular structure. There are two rings of duct tape and a shell tube welded between the upper and lower parts of the main building to form a three -cycle flue gas. The burner is located at the top of the body, and the flame can expand and burn.

     

    With the help of boilers and condensers, heat efficiency can reach 93%-100%.Built -in steam separators and external steam separators provide high quality dry steam, save fuel, reduce system scaling and extend life.

     
     
    Product Features

    1. In accordance with environmental requirements:

    The high quality and reliable combustion can cause the fuel to burn fully and significantly reduce the harmful emission of flue gas. 

     

    2. Evaporation may be increased:

    Steam generators can be modulated in many units (unlimited number) and controlled by computers. Total evaporation can be freely increased.

     

    3. Installation is a whole:

    The installation may be connected to water, electricity and steam pipes to save installation time and energy.

     

    4.Reliable accessories:

    Combustion burners, control boxes, water treatment, valves, pumps and other high -quality household appliances.

     

    5. Excellent control system:

    Boilers have a perfectly automatic control and a safety -responsive device to implement an automatic water stop system and a low water level alarm and shut -down; automatic control of vapour pressure and over -pressure alarm.

     

    6. Good service:

    Technical consultation, technical services, installation instructions, regular and irregular visits to users at any time to provide quality and perfect service for users to be safe and to buy

    Safety Protection Steam Powered Electric Generator Wide Application 0

     

    Technical Parameters

    Main Technical Reference for Fuel (Gas) Steam Generator

    Item Unit LSS0.05 LSS0.1 LSS0.15 LSS0J2
    Rated evaporation Kg/h 50 100 150 200
    Rated Pressure PTEPREppoPressure MPa 0.4/0.7
    Rated steam temperature c 151/171
    Rated feed water temperature °C 20
    Evaporator efficiency / >92%
    Applicable Fuel / Gas light oil
    Theoretical fuel consumption Gas NM3/h 4 8 12 16
    Light Oil Kg/h 3.3 6.5 9.8 13
    Gas supply pressure mbar 60- 100
    water volume L <30
     

    Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.

     

     

    Configuration and Interface Size of Fuel (Gas) Steam Generator

     

    Item Unit LSS0.05 LSSO.l LSS0.15 LSS0.2

    Outward Size of Main Engine

     

    (length * width * height)

    / mm 620*620*830 690*690*968 750*750*1130 800*800*1286

    Transport Dimension

     

    /    t 206 252 303 350
    Mainframe Transport Weight DN mm G 1/2- Gl' Gl" G 1*
    Main Steam Valve Pipe Diameter DN mm Gl/2" Gl/2- Gl/2- Gl/2°
    Feed Water Valve DN mm G1 1/4” G11/4- G11/4- G11/4-
    Safety Valve Diameter DN mm Gf GF Gl" Gl"
    Drain Valve Pipe Diameter DN mm 133 133 159 159
     

    Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.

     

    Safety Protection Steam Powered Electric Generator Wide Application 1Safety Protection Steam Powered Electric Generator Wide Application 2

    Contact Details
    Henan Yuji Boiler Vessel Manufacturing Co., Ltd.

    Contact Person: Xu

    Send your inquiry directly to us
    Henan Yuji Boiler Vessel Manufacturing Co., Ltd.
    Jingye Park International Building, Xinxiang
    Tel:86-157-3893-9753
    Mobile Site Privacy Policy China Good Quality Biomass Steam Boiler Supplier. © 2019 - 2020 biomass-steamboiler.com. All Rights Reserved.